Solar Power System Kits
DC voltage solar well pump
solar well pump
DC voltage solar well pump

ERG30 LMPK Series Low Frequency Off Grid Solar Inverter (1-4KW)

    This is a multi-function inverter, special in north & south america market, combining functions of inverter and mppt solar charger controller, solar charger and battery charger to offer uninterruptible power support with portable size. The comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and selectable input voltage based on different applications.
contact now
    • Features & Benefits

Specification

MODELERG30-1012 LMPKERG30-1024 LMPKERG30-1512 LMPKERG30-1524 LMPKERG30-2012 LMPKERG30-2024 LMPKERG30-3012 LMPKERG30-3024 LMPKERG30-3048 LMPKERG30-4024 LMPKERG30-4048 LMPK
Nominal Battery System Voltage12VDC24VDC12VDC24VDC12VDC24VDC12VDC24VDC48VDC24VDC48VDC
INVERTER OUTPUT
Reted Power1.0KW1.5KW2KW3KW4KW
Surge Rating (20ms)3.0KW4.5KW6.0KW9.0KW12KW
Capable Of Starting Electric Motor1HP2HP
WaveformPure sine wave/ same as input (bypass mode)
Nominal Output Voltage RMS100V/110V/120VAC (±10% RMS)
Output Frequency50Hz/60Hz±0.3 Hz
Inverter Efficiency(Peak)>88%
Line Mode Efficiency>95%
Power Factor1.0
Typical Transfer Time10ms(max)
AC INPUT
Voltage120VAC
Selectable Voltage Range80~135VAC(For Personal Computers)
Frequency Range50Hz/60Hz (Auto sensing) 40~80Hz
BATTERY
Minimum Start Voltage10.0VDC /10.5VDC for12VDC mode (*2 for 24VDC)20.0VDC~21.0VDC / 40.0VDC~42.0VDC
Low Battery Alarm10.5VDC±0.3V for12VDC mode (*2 for 24VDC)21.0VDC+/-0.6V /42.0VDC+/-1.2V
Low Battery Cut off10.0VDC±0.3V for12VDC mode (*2 for 24VDC)20.0VDC+/-0.6V /40.0VDC+/-1.2V
High Voltage Alarm16.0VDC±0.3V for12VDC mode (*2 for 24VDC)32.0VDC+/-0.6V /64.0VDC+/-1.2V
High Battery Voltage Recover15.5VDC±0.3V for12VDC mode (*2 for 24VDC)31.0VDC+/-0.6V / 62.0VDC+/-1.2V
Idle Consumption-Search Mode<25W when power saver on<50W when power saver on
CHARGER
Output VoltageDepends on battery type
Charger AC Input Breaker Rrating10A30A40A
Overcharge Protection S.D.15.7VDC for 12VDC mode (*2 for 24VDC mode)31.4VDC/62.8VDC
Maximum Charge Current35A20A45A25A65A35A75A45A30A65A35A
BYPASS&PROTECTION
Input Voltage WaveformSine wave (grid or generator)
Nominal Input Frequency50Hz or 60Hz
Overload Protection (SMPS Load)Circuit breaker
Output Short Circuit ProtectionCircuit breaker
Bypass Breaker Rating10A30A40A
Max Bypass Current30Amp40Amp
SOLAR CHARGER
Maximum PV Array Power600W1200W600W1200W600W1200W600W1200W1600W2400W3200W
Maximum PV Charge Current40A45A60A
DC Voltage12V/24V atuo work24V/48V atuo work
MPPT Range @ Operating Voltage16~100VDC32~145VDC @ 24V / 64~145VDC @ 48V
Maximum PV Array Open Circuit Voltage100VDC145VDC
Maximum Efficiency>98%
Standby Power Consumption2W
MECHANICAL SPECIFICATIONS
MountingWall Mount
Dimensions (W*H*D)423*247*197mm597x247x197mm
Net Weight (Solar CHG) kg18.518.419.519.423.532.228.72723.341.339.4
Shipping Dimensions(W*H*D)570*355*300mm750*335*300mm
Shipping Weight (Solar CHG) kg21.521.422.422.525.825.631.229.625.144.742.8
OTHER
Operation Temperature Range0°C to 40°C
Storage Temperature-15°C to 60°C
Audible Noise60dB MAX
DisplayLED+LCD
Standard Warranty1 year


Service Online

+86-158-9628-8746 / +86-185-2088-1117